ProStructures Dataset Migration
ProStructures datasets-the subfolders of WorkSpace\ProStructures\Localised\-were migrated to the CONNECT edition as ProStructures-extended workspaces. However, files that are common to most datasets and that are not typically modified by users were moved to programInstalDirectory\ProStructures\Defaults\.
The following table lists the folders and files in a typical SS8 Localised subfolder and where the files are in the CONNECT Edition. Related CONNECT Edition configuration variables are also listed.
SS8 Dataset > CONNECT Edition | |
---|---|
…\WorkSpace\ProStructures\Localised\datasetName\ | |
+
Bracings\ | +
xxx.mdb
| |
$(PS_BRACINGDATABASE) for
.mdb files
Move to workSpace\Standards\ProStructures\Bracing\ |
+ Data\ | |
| +
MechancialDevices\ | |
| | + xxx.bmp, xxx.dgn |
$(PS_MECHANICALDEVICEIMAGES) for
.bmp files
$(PS_MECHANICALDEVICES) for .dgn files Moved to product\Default\appl\Rebar\MechanicalDevices\ |
| | + CouplersHeadersAndMore3Dand2D.dgnlib | Deleted |
| +
MechanicalDevices.mdb
| | |
$(PS_MECHANICALDEVICESDB)
Moved to product\Default\appl\Rebar\MechanicalDevices\ |
| +
ProStructureMaterial.mdb
| | | | |
$(PS_MATERIALFILE)
Move to workSpace\Standards\ProStructures\Materials\ |
| +
Pro_st3d.fdf
| | |
$(PS_FREEDESCRIPTIONFILE)
Move to workSpace\Standards\ProStructures\Data\ |
| +
Pro_st3d.hdt
| | |
$(PS_HOLEDIAMETERTABLE)
Moved to product\Default\appl\MechanicalFasteners\Bolts\ |
| +
Pro_st3d.ldt
| | |
$(PS_LINEDISPLAYDESCRIPTIONFILE)
If exists, move to workSpace\Standards\ProStructures\Data\ |
| +
Pro_st3d.mdf
| | |
$(PS_MODIDESCRIPTIONFILE)
If exists, move to workSpace\Standards\ProStructures\Data\ |
| +
Pro_st3d.pdc
| | |
$(PS_PLATEDESCRIPTIONFILE)
Move to workSpace\Standards\ProStructures\Data\ |
| +
Pro_st3d.pit
| | |
$(PS_PROCESSDESCRIPTIONFILE)
Move to workSpace\Standards\ProStructures\Data\ |
| +
Pro_st3d.pod
| | | | |
$(PS_PARTORGINFILE)
If exists and is not zero bytes long, move to workSpace\Standards\ProStructures\Data\ |
| +
Pro_st3d.ptt
| |
$(PS_PLATETHICKTABLE)
Moved to product\Default\appl\Plates\ |
+ Dgnlib\ | $(MS_DGNLIBLIST) |
| +
ProConcreteDetailingSymbolsStyles.dgnlib
| + ProConcreteDrawingSeed.dgnlib |
|
| | | Moved to product\Default\Dgnlib\DrawComp\ |
| + ProStructures3DModeling.dgnlib | |
|
| |
Moved to
product\Default\Dgnlib\
See "ProStructures3DModeling" following this table. |
+ EEDs\ | |
| +
Bentley.EED
| + BentleyGroup.EED | | |
$(PS_USEREED)
$(PS_GROUPUSEREED) Moved to product\Default\appl\Data\EED\ |
| +
xxx.EED (for parts)
| + xxx.EED (for groups) | || | | | |
$(PS_USEREED)
$(PS_GROUPUSEREED) Move to workSpace\Standards\ProStructures\Data\EED\ and set PS_USEREED and PS_GROUPUSEREED in a workspace configuration file. |
| + EED.txt | Deleted |
| + UseGroupEedDefinition.txt | |
+ FactorySettings\ | |
| +
<unitSystem>\
| + xxx.fac, xxx.sve | |
$(PS_FACTORYSETTINGSPATH) for
.sve/.fac files
Moved to product\Default\appl\FactorySettings\<units>\ See "FactorySettings" following this table. |
+
Format\
| || || + xxx.dgn | || + xxx.frm, xxx.mkn, xxx.scl, | xxx.tra |
$(PS_DRAWINGFRAMES) for
.dgn files
$(PS_DRAWINGFRAMEDEFINITION) for .frm files $(PS_MARKNUMBERDEFINITION) for .mkn files$(PS_DRAWINGSCALETEMPLATE) for .scl files $(PS_DRAWINGTRANSLATION) for .tra filesMoved to product\Default\Details\Frames<units>\ See "Drawing Frames/Borders" following this table.Move to workSpace\Standards\ProStructures\Details\Frames\ |
+
Partlist\
| | + xxx.lbl, xxx.lst| | | || | |
$(PS_PARTLISTTEMPLATES) for standard
.lbl/.lst files
$(PS_CONCRETEPARTLISTTEMPLATES) for concrete .lst files Move standard templates to workspace\Standards\ProStructures\Partlist\Move concrete templates and bar bending schedules to workSpace\Standards\ProStructures\Partlist\Concete\ |
| +
BMP\
| | + xxx.bmp | | |
$(PS_PARTLISTIMAGES) for
.bmp files
Moved to product\Default\appl\Partlist\Images\ See "Partlist Images" following this table. |
| + BS8666_xxx.bmp | Deleted |
| + partlist_readme.pdf, etal. | Deleted. Content added to the help. |
| + PCBS_Dynamic\ & PCBS_Static\ | |
| | +
xxx.lst
| | |
Move to Australia\Standards\ProStructures\Partlist\Concrete\ and NewZealand\Standards\ProStructures\Partlist\Concirete\ |
| + <logoImage>.<imageExt> | Deleted. See "Partlist Logos" following this table. |
+ Resource\ | Deleted |
+
Seeds\
| + xxx.dgn | |
$(PS_SEEDFILES)
for
*.dgn
Moved to product\Default\Seed\appl<units>\ See "Seed Files" following this table. |
+ Styles\ | |
| + BoltStyles\ | |
| | +
<unitSystem>\
| | + xxx.bsy | | | |
$(PS_BOLTINGASSEMBLIES) for
.bsy files
Move to workSpace\Standards\ProStructures\ MechanicalFasteners\Bolts\ |
| | +
PsBoltList.bls
| | | | |
$(PS_BOLTINGASSEMBLIESLIST)
Move to workSpace\Standards\ProStructures\MechanicalFasteners\Bolts\ |
| + DetailStyles\ | |
| | +
<unitSystem>\
| | + xxx.stx |
$(PS_DETAILSTYLES) for
.stx files
Move to workSpace\Standards\ProStructures\Details\Styles\ |
| + ElevationflagStyles\ | |
| | +
<unitSystem>\
| | | | + xxx.bmp| | + xxx.ksy |
$(PS_ELEVATIONFLAGIMAGES) for
.bmp files
$(PS_ELEVATIONFLAGSTYLES) for .ksy files Moved to product\Default\appl\ElevationFlags\Move to workSpace\Standards\ProStructuers\ElevationFlags\ |
| | +
PsKoteFlagList.bls
| | | | |
$(PS_ELEVATIONFLAGSTYLESLISTFILE)
Move to workSpace\Standards\ProStructures\ElevationFlags\ |
| + FastenerStyles\ | |
| | + AnchorBoltBendStyles\ | |
| | | +
<unitSystem>\
| | | + xxx.xml | | | |
$(PS_ANCHORBOLTSBENT) for
.xml files
Move to workSpace\Standards\ProStructures\MechanicalFasteners\AnchorBoltsBent\ |
| | + AnchorBoltHookStyles\ | |
| | | +
<unitSystem>\
| | | + xxx.xml | | | |
$(PS_ANCHORBOLTSHOOK) for
.xml files
Move to workSpace\Standards\ProStructures\MechanicalFasteners\AnchorBoltsHook\ |
| | + AnchorBoltsStraightStyles\ | |
| | | +
<unitSystem>\
| | | + xxx.xml | | | |
$(PS_ANCHORBOLTSPLATE) for
.xml files
Move to workSpace\Standards\ProStructures\MechanicalFasteners\AnchorBoltsPlate\ |
| | + DowelBendStyles\ | |
| | | +
<unitSystem>\
| | | + xxx.xml | | | |
$(PS_DOWELSBENT) for
.xml files
Move to workSpace\Standards\ProStructures\ MechanicalFasteners\DowelsBent\ |
| | + DowelsHookStyles\ | |
| | | +
<unitSystem>\
| | | + xxx.xml | | | |
$(PS_DOWELSHOOK) for
.xml files
Move to workSpace\Standards\ProStructures\ MechanicalFasteners\DowelsHook\ |
| | + HeadBoltStyles\ | |
| | | +
< unitSystem >\
| | | + xxx.xml | | | |
$(PS_ANCHORBOLTSHEAD) for
.xml files
Move to workSpace \Standards\ProStructures\ MechanicalFasteners\AnchorBoltsHead\ |
| | + StudHexStyles\ | |
| | | +
<unitSystem>\
| | | + xxx.xml | | | |
$(PS_STUDSHEXHEAD) for
.xml files
Move to workSpace\Standards\ProStructures\ MechanicalFasteners\StudsHexHead\ |
| | + StudRoundStyles\ | |
| | +
<unitSystem>\
| | + xxx.xml | | |
$(PS_STUDSROUNDHEAD) for
.xml files
Move to workSpace\Standards\ProStructures\ MechanicalFasteners\StudsRoundHead\ |
| + HoleDisplayStyles\ | |
| | +
<unitSystem>\
| | | | + xxx.bmp| | + xxx.hsy | | | |
$(PS_HOLEDISPLAYSTYLEIMAGES) for
.bmp
files
$(PS_HOLEDISPLAYSTYLES) for .hsy files Moved to product\Default\appl\Details\HoleDisplay\ Move to workSpace\Standards\ProStructures\Details\HoleDisplay\ |
| | +
PsHoleDisplayList.bls
| | | | |
$(PS_HOLEDISPLAYSTYLESLISTFILE)
Move to workSpace\Standards\ProStructures\Details\HoleDisplay\ |
| + PosflagStyles\ | |
| | +
<unitSystem>\
| | | | + xxx.bmp| | + xxx.psy |
$(PS_POSITIONFLAGIMAGES) for
.bmp files
$(PS_POSITIONFLAGSTYLES) for .psy files Moved to product\Default\appl\PositionFlags\Move to workSpace\Standards\ProStructures\PositionFlags\ |
| | +
PsPosFlagList.bls
| | |
$(PS_POSITIONFLAGSTYLESLISTFILE)
Move to workSpace\Standards\ProStructures\PositionFlags\ |
| + WeldStyles\ | |
| +
<unitSystem>\
| | + xxx.bmp| + xxx.wsy |
$(PS_WELDSTYLEIMAGES) for
.bmp files
$(PS_WELDSTYLES) for
.wsy files
Moved to product\Default\appl\Welds\ Move to workSpace\Standards\ProStructures\Welds\ |
| +
PsWeldList.bls
| |
$(PS_WELDSTYLESLISTFILE)
Move to workSpace\Standards\ProStructures\Welds\ |
+ Temp\ | |
| +
<unitSystem>\
| | + xxx.sve |
$(PS_TEMPLATESLASTUSED) for
.sve files (excluding
xxxWndCfg.sve files)
Move to workSpace\Standards\ProStructures\Varia\LastUsed\ |
| + xxxWndCfg.sve | Deleted. Recreated in $(PS_WNDCFG) as dialogs are opened. |
| + PcConfig.def | Deleted |
| + Other temporary files | Deleted. Recreated in $(MS_SCR) as needed. |
+ UserBlocks\ | |
| +
pc3ddata.bcd
| | |
$(PS_USERPARTCENTERDB)
Move to workSpace\Standards\ProStructures\UserParts\ |
| +
anchors\
| | | | | + xxx.dgn| | | | | + xxx.mdb |
$(PS_DISPATCHCELL) for
.dgn files
$(PS_DISPATCHCELLDATABASE) for .mdb files Move to workSpace\Standards\ProStructures\DispatchCells\ |
| +
BenchMarks\
| | + xxx.dgn | | |
$(PS_BENCHMARKUSER) for
.dgn files
Moved to product\Default\appl\BenchMarks<units>\ See "Benchmarks/North Arrows" following this table. |
| +
CastIn Elements\
| | + xxx.dgn | | |
$(PS_PANELINSERT) for
.dgn files
Moved to product\Default\appl\PanelInserts\<units> See "Concrete Panel Inserts" following this table. |
| +
Dowels\
| | + xxx.mdb | | |
$(PS_DOWELSDATABASE) for
.mdb files
Move to workSpace\Standards\ProStructures\ MechanicalFasteners\Dowels\ |
| +
ElevationFlags\
| | + xxx.dgn, xxx.bmp | | |
$(PS_ELEVATIONFLAGUSER) for
.dgn and optional
.bmp files
Moved to product\Default\appl\ElevationFlags\<units> See " Elevation Flag Symbols" following this table. |
| +
Foot Anchors\
| | + xxx.dgn | | |
$(PS_DISPATCHCELL) for
.dgn files
Moved to product\Default\appl\DispatchCells\<units> See " Dispatch Cells" following this table. |
| +
GridAxis\
| | + xxx.dgn | || | |
$(PS_GRIDBUBBLEUSER) for
.dgn files
Move to product\Default\appl\WorkFrames\GridBubbles<units>\ See " Grid Bubbles" following this table. |
| + Handrail\ | |
| | +
Fillings\
| | | + xxx.dgn | | | |
$(PS_HANDRAILFILLINGUSER) for
.dgn files
Moved to product\Default\appl\Handrails\Fillings<units>\ See " Handrail Fillings" following this table. |
| | +
Posts\
| | + xxx.dgn | | |
$(PS_HANDRAILPOSTUSER) for
.dgn files
Moved to product\Default\appl\Handrails\Posts<units>\ |
| +
HoleDisplayBlocks\
| | + xxx.dgn | | |
$(PS_HOLEDISPLAYUSER) for
.dgn files
Moved to product\Default\appl\HoleDisplay<units>\ See "HoleDIsplay Symbols" following this table. |
| + Joist\ | Deleted |
| +
ManualCut\
| | + xxx.dgn | | |
$(PS_MANUALCUTUSER) for
.dgn files
Moved to product\Default\appl\Details\ManualCuts\<units>\ See " Manual Cut Symbols" following this table. |
| +
OpenWebJoistBlocks\
| | | | + xxx.dgn, xxx.mdb |
$(PS_JOISTUSER)
for
.dgn files
$(PS_JOISTDATABASE) for .mdb files Move to workSpace\Standards\ProStructures\Joists\ |
| +
PositionFlags\
| | + xxx.dgn | | |
$(PS_POSITIONFLAGUSER) for
.dgn files
Moved to program\Default\appl\PositionFlags\<units> See " Position Flag Symbols" following this table. |
| +
StairSteps\
| | + xxx.dgn, xxx.bmp | | |
$(PS_STAIRSTEPUSER) for
.dgn and optional .bmp
files
Moved to product\Default\appl\Stairs\Steps<units>\ See " Stair Steps" following this table. |
| +
Th(r)eaded Inserts\
| | + xxx.dgn | | |
$(PS_DISPATCHCELL) for
.dgn files
Moved to product\Default\appl\DispatchCells\<units> See "Dispatch Cells" following this table. |
| + Welds\ | |
| | +
Flags\
| | | + xxx.dgn | | | |
$(PS_WELDFLAGUSER) for
.dgn files
Moved to program\Default\appl\Welds\Flags<units>\ See " Weld Flags" following this table. |
| | +
Opposite\
| | | | | | + Opposite1.bmp| | | + xxx.dgn, xxx.bmp | | | |
$(PS_WELDOPPOSITE) for
Opposite1.bmp
$(PS_WELDOPPOSITEUSER) for pairs of .dgn/.bmp files Moved to product\Default\Appl\Welds\Opposite\Moved to product\Default\Appl\Welds\Opposite<units>\ See " Weld Opposite Signs" following this table. |
| | +
Signs\
| | | | + Sign1.bmp| | through | | Sign18.bmp| | + xxx.dgn, xxx.bmp | | |
$(PS_WELDSIGN)
for
Sign1.bmp through
Sign18.bmp
$(PS_WELDSIGNUSER) for pairs of .dgn/.bmp files Moved to product\Default\Appl\Welds\Signs\. . Moved to product\Default\Appl\Welds\Signs<units>\ See " Weld Signs" following this table. |
| +
xxx\
| | |
$(PS_USERPARTS)
Move directory to workSpace\Standard\ProStructures\UserParts\ See "UserBlocks to UserParts" following this table. |
+ Varia\ | |
+
<unitSystem>\
+ xxx.tpl |
$(PS_TEMPLATEPATH) for
.tpl files
Move to workSpace\Standards\ProStructures\Varia\ |
ProStructures3DModeling.dgnlib
The US-specific levels-the ones named G-xxx, S-xxx, and SR-xxx-were moved from the ProStructures3DModeling.dgn into a new USA_Canada3DModeling.dgnlib file. USA_Canada3DModeling.dgnlib is delivered only in the USA_Canada_Imperial and USA_Canada_Metric workspaces.
FactorySettings
A generic set of metric and Imperial factory settings was moved to the product directory. Dataset-specific factory settings should be moved to workSpace\Standards\ProStructures\FactorySettings and PS_FACTORYSETTINGS should be added to a workspace configuration file.
Also, the .fac extension is for detail style dialogs. Factory settings for all other dialogs use a .sve extension. You may need to rename files.
Drawing Frames/Borders
A commonly-used set of metric and Imperial drawing frame/border .dgn files was moved to the product directory. Any dataset-specific .dgn files should be moved to workSpace\Standards\ProStructures\Details\Frames and PS_DRAWINGFRAMES should be added to a workspace configuration file.
Partlist Images
In SS8, references to external image files in templates were relative to the location of the template, e.g. BMP\cuttingforms.jpg in the "cutting" templates. This setup is still valid in the CONNECT Edition. Simply move the image files while maintaining the same relationship to the templates, e.g. workSpace\Standards\ProStructures\Partlist\BMP\cuttingforms.jpg.
A more flexible setup is available in the CONNECT Edition. A variable named CfgVar.StaticImagePath is available in templates for the folder containing external image files. The value is the current setting of $(PS_PARTLISTIMAGE) in standard templates and $(PS_CONCRETEPARTLISTIMAGE) in concrete templates.
The delivered templates for cut shapes are updated to use CfgVar.StaticImagePath for the folder holding the "cut" images. The default setting for PS_PARTLISTIMAGE finds them in the product directory.
Partlist Logos
A product or company logo is a common feature in a partlist or bill of material. In SS8, the logo is either embedded in the template or referenced with a hard-coded (relative) path and file name.
A more customizable setup is available in the CONNECT Edition. A variable named CfgVar.LogoImageFIle is available in templates to specify an external logo image file. The value is the current setting of $(PS_PARTLISTLOGO).
The delivered templates are updated to use CfgVar.LogoImageFile for all logos. The default setting for PS_PARTLISTLOGO is a ProStructures CONNECT Edition image. Changing the PS_PARTLISTLOGO value will customize a delivered template with your company logo without modifying the template.
Seed Files
A default set of metric and Imperial seed files were moved to the product directory. Dataset-specific seed files should be moved to workSpace\Standards\ProStructures\Seeds\ and PS_SEEDFILES and MS_DESIGNSEED should be set in a workspace configuration file.
Dispatch Cells
A default set of metric and Imperial dispatch cell .dgn files was moved to the product directory. Dataset-specific .dgn files should be moved to workSpace\Standards\ProStructures\DispatchCells and PS_DISPATCHCELL should be set in a workspace configuration file.
Benchmarks/North Arrows
A default set of metric and Imperial benchmark/north arrow .dgn files was moved to the product directory. Dataset-specific .dgn files should be moved to workSpace\Standards\ProStructures\Benchmarks and PS_BENCHMARKUSER should be set in a workspace configuration file.
Concrete Panel Inserts
A default set of metric and Imperial concrete panel insert .dgn files was moved to the product directory. Dataset-specific .dgn files should be moved to workSpace\Standards\ProStructures\PanelInserts and PS_PANELINSERT should be set in a workspace configuration file.
Elevation Flag Symbols
The common (and duplicated) example files for user-defined elevation flag symbols were moved to the product directory. Dataset-specific .dgn and .bmp files should be moved to workSpace\Standards\ProStructures\ElevationFlags and PS_ELEVATIONFLAGUSER should be set in a workspace configuration file.
Grid Bubbles
The common (and duplicated) example files for user-defined grid bubbles were moved to the product directory. Dataset-specific .dgn files should be moved to workSpace\Standards\ProStructures\WorkFrames\GridBubbles and PS_GRIDBUBBLEUSER should be set in a workspace configuration file.
Handrail Fillings
The common (and duplicated) example files for user-defined handrail fillings were moved to the product directory. Dataset-specific .dgn files should be moved to workSpace\Standards\ProStructures\Handrails\Fillings and PS_HANDRAILFILLINGUSER should be set in a workspace configuration file.
Handrail Posts
The common (and duplicated) example files for user-defined handrail posts were moved to the product directory. Dataset-specific .dgn files should be moved to workSpace\Standards\ProStructures\Handrails\Posts and PS_HANDRAILPOSTUSER should be set in workspace configuration file.
HoleDisplay Symbols
A typical set of symbols to use in place of true geometry for holes in drawings was moved to the product directory. Any dataset-specific .dgn files should be moved to workSpace\Standards\ProStructures\Details\HoleDisplay\ and PS_HOLEDISPLAYUSER should be set in a workspace configuration file.
Manual Cut Symbols
The common (and duplicated) example files for user-defined manual cut symbols were moved to the product directory. Dataset-specific .dgn files should be moved to workSpace\Standards\ProStructures\Details\ManualCuts and PS_MANUALCUTUSER should be set in a workspace configuration file.
Position Flag Symbols
The common (and duplicated) example files for user-defined position flag symbols were moved to the product directory. Dataset-specific .dgn files should be moved to workSpace\Standards\ProStructures\PositionFlags and PS_POSITIONFLAGUSER should be set in a workspace configuration file.
Stair Steps
The common (and duplicated) example files for user-defined stair step were moved to the product directory. Dataset-specific .dgn and .bmp files should be moved to workSpace\Standards\ProStructures\Stairs\Steps and PS_STAIRSTEPUSER should be set in a workspace configuration file.
Weld Flags
The common (and duplicated) example files for user-defined flags for weld symbols were moved to the product directory. Dataset-specific .dgn files should be moved to workSpace\Standards\ProStructures\Welds\Flags and PS_WELDFLAGUSER should be set in a workspace configuration file.
Weld Opposite Signs
The common (and duplicated) example files for user-defined opposite-side signs for weld symbols were moved to the product directory. Dataset-specific .dgn and .bmp files should be moved to workSpace\Standards\ProStructures\Welds\Opposite and PS_WELDOPPOSITEUSER should be set in a workspace configuration file.
Weld Signs
The common (and duplicated) example files for user-defined signs for weld symbols were moved to the product directory. Dataset-specific .dgn and .bmp files should be moved to workSpace\Standards\ProStructures\Welds\Signs and PS_WELDSIGNUSER should be set in a workspace configuration file.
UserBlocks To UserParts
In SS8, the UserBlocks directory was the default location of a directory tree containing blocks (design files) managed by the Block Center tool.
In the CONNECT Edition, the User Part Center tool manages the parts (design files) in the directories listed in the PS_USERPARTS configuration variable. Parts in subdirectories are not managed unless the subdirectories are listed in $(PS_USERPARTS). The default setting is all first-level subdirectories of workSpace\Standards\ProStructures\UserParts\.